Brand Name : GSKA

Model Number : Battery Short-Circuit Test Chamber

Certification : CE SGS ROHS UL CE

Place of Origin : Dongguan China

MOQ : Negotiate

Price : Negotiate

Payment Terms : L/C, T/T

Supply Ability : 1000 Set / Sets per Month

Delivery Time : 10-60days after confirmed payment or by contract stipulation

Packaging Details : Export package

Impulse Voltage : AC 1kv/1.2-50us (Peak) Lmin

Voltage Resolution : 0.01V

Rated test current : ≥10000A

Maximum operating current duration : ≥10ms5.5.

Voltage acquisition range : 0-1000v

Temperature acquisition accuracy : ≤±1.5ºC

Contact Now

AC 1KV Impulse Voltage Short Circuit Tester For Lithium Battery

Product use:


The battery pack short-circuit equipment is mainly used for the safety verification test of power battery cells, monomers, modules, PACK-level battery packs and structural parts of new energy projects. Simulate the short-circuit situation of battery cells, cells, modules, and PACK-level battery packs during use, transportation and storage to evaluate the safety performance of batteries. Present the actual use of battery packs or systems in the laboratory, find and solve problems, optimize product design, and improve product quality

Product manual:


1. Application of battery pack short circuit equipment: It is mainly used for the safety verification test of power battery cells, monomers, modules, PACK and other battery packs and structural parts of new energy projects. Simulate the short-circuit situation of battery cells, monomers, modules and PACK battery packs during use, transportation and storage to evaluate the safety performance of the battery. Present the actual use of battery packs or systems in the laboratory, find and solve problems, optimize product design, and improve product quality.


2. The battery pack short-circuit equipment is composed of a short-circuit control box, a vacuum arc extinguishing device, a short-circuit terminal wiring, a data acquisition system and a computer for data analysis.

Overview of battery pack short-circuit equipment design:


The short-circuit equipment is designed based on the requirements of various battery short-circuit test standards, that is, it meets CB31467.31CB31485UU25801SAE J24641SAEJ2929UN38.3ECER100IEC6213UL1642 Qc / T 743 and "863i Plan" Energy-Saving and New Energy Vehicle Major Projects - 2008 EV Lithium-ion Power Battery Performance Test Specifications and other standards; short-circuit devices must meet the internal resistance range according to the standard <5m or >5m2&<10m or >10m2&<20m or >40m&<50m or >80m&100m2 to obtain the maximum short-circuit current of the test; the circuit design of the short-circuit device can also withstand the impact of a large current of 16000A, so we choose industrial grade mechanical suction

fulfill the standard:


1. CB31467.3 "Lithium-ion power battery packs and systems for electric vehicles No. 3: Safety requirements and test methods"


2.CB/T 31485-2015 "Safety Requirements and Test Methods for Power Batteries for Electric Vehicles"


QC/ T 743-2006 "Lithium-ion batteries for electric vehicles"


CB/T 18332-2015 "Zinc Air Batteries for Electric Vehicles"


5. Ji 2580-2013 "Electric Vehicle Battery Safety Standards"


6. SAND99-0497 "American Automotive Power Battery Test Standard"


7. SAE J2464 "Electric and Hybrid Electric Vehicle Charging and Energy Storage Safety and Abuse Test"


8. SAE J2929-2013 "Safety Standard for Electric and Hybrid Vehicle Propulsion Battery Systems." Lithium-based rechargeable battery" and

other test standards

technical parameter

Impulse voltage

AC 1kv/1.2-50us (peak) lmin

Action characteristics

Cold state pull-in voltage 66%Us

Cold release voltage bucket 30%Us,*5%Us

Action time

Pull-in time/release time: 20ms

Maximum operating current duration

≥10ms5.5.

Voltage acquisition range

0-1000v

Voltage resolution

0.01v

Voltage measurement accuracy

±0.5% (full scale)

Voltage set channel

Standard 1 channel, isolated between channels, can support expansion

Rated test current

≥10000A

Maximum operating current

≥15000A

Maximum pulse current

≥16000A

Current acquisition range

0-15000A

Current measurement accuracy

1000A-15000A, the accuracy is ±0.5%

Current resolution

0.1A

Current acquisition channel

Standard 1 channel, isolated between channels, can support expansion

Temperature acquisition range

-200-1350ºC

Temperature acquisition accuracy

≤±1.5ºC

temperature acquisition channel

Standard 12 channels, isolated between channels, can support expansion

Data collection frequency

7.19.1.10mslhr, 19 kinds can be set (if the test channel is more than
15 channels at the same time, the acquisition frequency can be set as
20ms-1hr)

7.19.2. Due to the high frequency of data collection, the data read and
recorded by the device in real time can be consistent with the actual data

Runtime recording accuracy

≤±0.1% (full scale)

Test Data

The voltage/current/temperature data is displayed and recorded on the control
software in real time, and the voltage/current/temperature/time curve is
automatically drawn

way to control

Using remote touch screen control + remote control + computer (for data
analysis and video monitoring)

short circuit

Mechanical pull-in (contactor pneumatic pull-in, synchronous forced disconnection
device when disconnected) + vacuum arc extinguishing device

Short circuit cut-off condition

Short circuit can be stopped by setting voltage and time parameters

Device circuit resistance

<5m,>5m&<10m,>10m&<20m,>40m&<50m,>80m&<100m, the corresponding
rated test currents satisfy 10000A, 10000A, 5000A, 5000A, 3000A, respectively.
It includes the electrical components inside and outside the device + the internal
resistance of the cable + the internal resistance of the fixture.

Short circuit terminal wiring

<5m,>5m&<10m,>10m&<20m,>40m&<50m,>80m&<100m, 1 pair each,
The length of the wrong line is not less than 6 meters, and there are 5 pairs in total.
The cross-sectional area of the soft copper wire at the output end of the device is not
less than 2000mm²

Short circuit internal resistance switching mode

Manual switching, one end of the short-circuit terminal wire is a through nose,
which can be fixed by bolts with the screw holes of the contactor, and the other
end is a battery clamp with copper terminals, which can be directly clamped on
the positive and negative poles of the battery to replace It can be replaced by
simply removing the fixing bolts

Short circuit test response time
(short circuit start to close to fully closed)

≤10ms

Mechanical life

300,000 times

Electrical life

50,000 times

Remote control distance

No solid barrier 10m

short circuit time

0-9999H59M59S can be set

AC 1KV Impulse Voltage Short Circuit Tester For Lithium Battery

Customer Support Services:

Ø Installation


Ø Training (Training customer employees)


Ø Preventative maintenance


Ø Replacement parts


Ø Assistance via phone or internet


Ø On-site diagnosis and repair/online diagnosis and repair


Product Tags:

AC 1KV Short Circuit Tester

      

10000A Short Circuit Tester

      

SGS Lithium Battery Short Circuit Tester

      
Cheap AC 1KV Impulse Voltage Short Circuit Tester For Lithium Battery for sale

AC 1KV Impulse Voltage Short Circuit Tester For Lithium Battery Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Guangdong ALI Testing Equipment Co,.Ltd
*Subject:
*Message: